Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed J ; : 100729, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38657859

RESUMO

Idiopathic pulmonary fibrosis (IPF) diagnosis is still the diagnosis of exclusion. Differentiating from other forms of interstitial lung diseases (ILDs) is essential, given the various therapeutic approaches. The IPF course is now unpredictable for individual patients, although some genetic factors and several biomarkers have already been associated with various IPF prognoses. Since its early stages, IPF may be asymptomatic, leading to a delayed diagnosis. The present review critically examines the recent literature on molecular biomarkers potentially useful in IPF diagnostics. The examined biomarkers are grouped into breath and sputum biomarkers, serologically assessed extracellular matrix neoepitope markers, and oxidative stress biomarkers in lung tissue. Fibroblasts and complete blood count have also gained recent interest in that respect. Although several biomarker candidates have been profiled, there has yet to be a single biomarker that proved specific to the IPF disease. Nevertheless, various IPF biomarkers have been used in preclinical and clinical trials to verify their predictive and monitoring potential.

2.
Ecotoxicol Environ Saf ; 271: 115965, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38244513

RESUMO

Glyphosate (GLP) and GLP-based herbicides (GBHs), such as polyethoxylated tallow amine-based GLP surfactants (GLP-SH), developed in the late 70', have become the most popular and controversial agrochemicals ever produced. Nowadays, GBHs have reached 350 million hectares of crops in over 140 countries, with an annual turnover of 5 billion and 11 billion USD in the U.S.A. and worldwide, respectively. Because of the highly efficient inhibitory activity of GLP targeted to the 5-enolpyruvylshikimate-3-phosphate synthase pathway, present in plants and several bacterial strains, the GLP-resistant crop-based genetic agricultural revolution has decreased famine and improved the costs and quality of living in developing countries. However, this progress has come at the cost of the 50-year GBH overuse, leading to environmental pollution, animal intoxication, bacterial resistance, and sustained occupational exposure of the herbicide farm and companies' workers. According to preclinical and clinical studies covered in the present review, poisoning with GLP, GLP-SH, and GBHs devastatingly affects gut microbiota and the microbiota-gut-brain (MGB) axis, leading to dysbiosis and gastrointestinal (GI) ailments, as well as immunosuppression and inappropriate immunostimulation, cholinergic neurotransmission dysregulation, neuroendocrinal system disarray, and neurodevelopmental and neurobehavioral alterations. Herein, we mainly focus on the contribution of gut microbiota (GM) to neurological impairments, e.g., stroke and neurodegenerative and neuropsychiatric disorders. The current review provides a comprehensive introduction to GLP's microbiological and neurochemical activities, including deviation of the intestinal Firmicutes-to-Bacteroidetes ratio, acetylcholinesterase inhibition, excitotoxicity, and mind-altering processes. Besides, it summarizes and critically discusses recent preclinical studies and clinical case reports concerning the harmful impacts of GBHs on the GI tract, MGB axis, and nervous system. Finally, an insightful comparison of toxic effects caused by GLP, GBH-SH, and GBHs is presented. To this end, we propose a first-to-date survey of clinical case reports on intoxications with these herbicides.


Assuntos
Herbicidas , Exposição Ocupacional , Animais , 60658 , Glicina/toxicidade , Eixo Encéfalo-Intestino , Acetilcolinesterase , Herbicidas/toxicidade , Sistema Nervoso
3.
ACS Appl Mater Interfaces ; 15(42): 49595-49610, 2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37823554

RESUMO

We developed a procedure for selective 2,4-dimethylphenol, DMPh, direct electro-oxidation to 3,3',5,5'-tetramethyl-2,2'-biphenol, TMBh, a C-C coupled product. For that, we used an electrode coated with a product-selective molecularly imprinted polymer (MIP). The procedure is reasonably selective toward TMBh without requiring harmful additives or elevated temperatures. The TMBh product itself was used as a template for imprinting. We followed the template interaction with various functional monomers (FMs) using density functional theory (DFT) simulations to select optimal FM. On this basis, we used a prepolymerization complex of TMBh with carboxyl-containing FM at a 1:2 TMBh-to-FM molar ratio for MIP fabrication. The template-FM interaction was also followed by using different spectroscopic techniques. Then, we prepared the MIP on the electrode surface in the form of a thin film by the potentiodynamic electropolymerization of the chosen complex and extracted the template. Afterward, we characterized the fabricated films by using electrochemistry, FTIR spectroscopy, and AFM, elucidating their composition and morphology. Ultimately, the DMPh electro-oxidation was performed on the MIP film-coated electrode to obtain the desired TMBh product. The electrosynthesis selectivity was much higher at the electrode coated with MIP film in comparison with the reference nonimprinted polymer (NIP) film-coated or bare electrodes, reaching 39% under optimized conditions. MIP film thickness and electrosynthesis parameters significantly affected the electrosynthesis yield and selectivity. At thicker films, the yield was higher at the expense of selectivity, while the electrosynthesis potential increase enhanced the TMBh product yield. Computer simulations of the imprinted cavity interaction with the substrate molecule demonstrated that the MIP cavity promoted direct coupling of the substrate to form the desired TMBh product.

4.
Biosens Bioelectron ; 236: 115381, 2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37267687

RESUMO

Redox-active molecularly imprinted polymer nanoparticles selective for glyphosate, MIP-Gly NPs, were devised, synthesized, and subsequently integrated onto platinum screen-printed electrodes (Pt-SPEs) to fabricate a chemosensor for selective determination of glyphosate (Gly) without the need for redox probe in the test solution. That was because, ferrocenylmethyl methacrylate was added to the polymerization mixtures during the NPs synthesis so that the resulting MIP-Gly NPs contained covalently immobilized ferrocenyl moieties as the reporting redox ingredient, conferring these NPs with electroactive properties. MIP-Gly NPs of four different compositions were evaluated. The herein described approach represents a simple and effective way to endow MIP NPs with electrochemical reporting capabilities with neither the need to functionalize them post-synthesis nor to use electrochemical mediators present in the tested solution during the analyte determinations. MIP-Gly NPs synthesized using allylamine and squaramide-based monomers appeared most selective to Gly. The Pt-SPEs modified with MIP-Gly NPs were characterized with differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). Changes in the DPV peak originating from the oxidation of the ferrocenyl moieties in these MIP-Gly NPs served as the analytical signal. The DPV limit of detection and the linear dynamic concentration range for Gly were 3.7 pM and 25 pM-500 pM, respectively. Moreover, the selectivity of the fabricated chemosensors was sufficiently high to determine Gly successfully in spiked river water samples.


Assuntos
Técnicas Biossensoriais , Impressão Molecular , Nanopartículas , Polímeros Molecularmente Impressos , Polímeros/química , Impressão Molecular/métodos , Técnicas Biossensoriais/métodos , Nanopartículas/química , Eletrodos , Técnicas Eletroquímicas/métodos , Limite de Detecção
5.
Environ Sci Technol ; 57(27): 9898-9924, 2023 07 11.
Artigo em Inglês | MEDLINE | ID: mdl-37384557

RESUMO

The present article critically and comprehensively reviews the most recent reports on smart sensors for determining glyphosate (GLP), an active agent of GLP-based herbicides (GBHs) traditionally used in agriculture over the past decades. Commercialized in 1974, GBHs have now reached 350 million hectares of crops in over 140 countries with an annual turnover of 11 billion USD worldwide. However, rolling exploitation of GLP and GBHs in the last decades has led to environmental pollution, animal intoxication, bacterial resistance, and sustained occupational exposure of the herbicide of farm and companies' workers. Intoxication with these herbicides dysregulates the microbiome-gut-brain axis, cholinergic neurotransmission, and endocrine system, causing paralytic ileus, hyperkalemia, oliguria, pulmonary edema, and cardiogenic shock. Precision agriculture, i.e., an (information technology)-enhanced approach to crop management, including a site-specific determination of agrochemicals, derives from the benefits of smart materials (SMs), data science, and nanosensors. Those typically feature fluorescent molecularly imprinted polymers or immunochemical aptamer artificial receptors integrated with electrochemical transducers. Fabricated as portable or wearable lab-on-chips, smartphones, and soft robotics and connected with SM-based devices that provide machine learning algorithms and online databases, they integrate, process, analyze, and interpret massive amounts of spatiotemporal data in a user-friendly and decision-making manner. Exploited for the ultrasensitive determination of toxins, including GLP, they will become practical tools in farmlands and point-of-care testing. Expectedly, smart sensors can be used for personalized diagnostics, real-time water, food, soil, and air quality monitoring, site-specific herbicide management, and crop control.


Assuntos
Herbicidas , Materiais Inteligentes , Animais , Conservação dos Recursos Naturais , Plantas Geneticamente Modificadas , Agricultura
6.
J Mater Chem B ; 11(8): 1659-1669, 2023 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-36722440

RESUMO

Herein we described a post-imprinting modification of the imprinted molecular cavities for electrochemical sensing of a target protein. Imprinted molecular cavities were generated by following the semi-covalent surface imprinting approach. These mesoporous cavities were modified with a ferrocene 'electrochemical' tracer for electrochemical transduction of the target protein recognition. Electrochemical sensors prepared after post-imprinting modification showed a linear response in the concentration range of 0.5 to 50 µM. Chemosensors fabricated based on capacitive impedimetric transduction demonstrated that imprinted molecular cavities without post-imprinting modification showed better selectivity. Scanning electrochemical microscopy (SECM) was used for the surface characterization of imprinted molecular cavities modified with ferrocene electrochemical tracers. SECM analysis performed in the feedback mode monitor changes in the surface state of the ferrocene-modified polymer film. The kinetics of the mediator regeneration was almost 1.8 times higher on the non-imprinted surface versus the post-imprinting modified molecular imprinted polymer.


Assuntos
Impressão Molecular , Polímeros , Metalocenos , Polímeros/química , Microscopia Eletroquímica de Varredura , Proteínas
7.
ACS Appl Polym Mater ; 5(1): 223-235, 2023 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-36660253

RESUMO

The present research reports on in-water, site-specific photodeposition of glyphosate (GLP)-containing polyacrylamide (PAA-GLP) nanometer-thick films (nanofilms) on an inner surface of fused silica (fused quartz) microcapillaries presilanized with trimethoxy(octen-7-yl)silane (TMOS). TMOS was chosen because of the vinyl group presence in its structure, enabling its participation in the (UV light)-activated free-radical polymerization (UV-FRP) after its immobilization on a fused silica surface. The photodeposition was conducted in an aqueous (H2O/ACN; 3:1, v/v) solution, using UV-FRP (λ = 365 nm) of the acrylamide (AA) functional monomer, the N,N'-methylenebis(acrylamide) (BAA) cross-linking monomer, GLP, and the azobisisobutyronitrile (AIBN) UV-FRP initiator. Acetonitrile (ACN) was used as the porogen and the solvent to dissolve monomers and GLP. Because of the micrometric diameters of microcapillaries, the silanization and photodeposition procedures were first optimized on fused silica slides. The introduction of TMOS, as well as the formation of PAA and PAA-GLP nanofilms, was determined using atomic force microscopy (AFM), scanning electron microscopy with energy-dispersive X-ray (SEM-EDX) spectroscopy, and confocal micro-Raman spectroscopy. Particularly, AFM and SEM-EDX measurements determined nanofilms' thickness and GLP content, respectively, whereas in-depth confocal (micro-Raman spectroscopy)-assisted imaging of PAA- and PAA-GLP-coated microcapillary inner surfaces confirmed the successful photodeposition. Moreover, we examined the GLP impact on polymer gelation by monitoring hydration in a hydrogel and a dried powder PAA-GLP. Our study demonstrated the usefulness of the in-capillary micro-Raman spectroscopy imaging and in-depth profiling of GLP-encapsulated PAA nanofilms. In the future, our simple and inexpensive procedure will enable the fabrication of polymer-based microfluidic chemosensors or adsorptive-separating devices for GLP detection, determination, and degradation.

8.
Biosensors (Basel) ; 12(11)2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36421137

RESUMO

Instead of molecularly imprinting a whole protein molecule, imprinting protein epitopes is gaining popularity due to cost and solubility issues. Belonging to the matrix metalloproteinase protein family, MMP-1 is an interstitial collagenase that degrades collagen and may be involved in cell migration, cell proliferation, the pro-inflammatory effect, and cancer progression. Hence, it can serve as a disease protein biomarker and thus be useful in early diagnosis. Herein, epitopes of MMP-1 were identified by screening its crystal structure. To identify possible epitopes for imprinting, MMP-1 was cleaved in silico with trypsin, pepsin at pH = 1.3, and pepsin at pH > 2.0 using Peptide Cutter, generating peptide fragments containing 8 to 12 amino acids. Five criteria were applied to select the peptides most suitable as potential epitopes for MMP-1. The triphenylamine rhodanine-3-acetic acid (TPARA) functional monomer was synthesized to form a stable pre-polymerization complex with a selected template epitope. The complexed functional monomer was then copolymerized with 3,4-ethoxylenedioxythiophene (EDOT) using potentiodynamic electropolymerization onto indium−tin−oxide (ITO) electrodes. The composition of the molecularly imprinted poly(TPARA-co-EDOT) (MIP) was optimized by maximizing the film's electrical conductivity. Cyclic voltammetry was used to determine MMP-1 concentration in the presence of the Fe(CN)63−/Fe(CN)64− redox probe actuating the "gate effect." A calibration curve was constructed and used to determine the usable concentration range and the limit of detection as ca. 0.001 to 10.0 pg/mL and 0.2 fg/mL MMP-1, respectively. Finally, the MMP-1 concentration in the A549 human lung (carcinoma) culture medium was measured, and this determination accuracy was confirmed using an ELISA assay.


Assuntos
Impressão Molecular , Humanos , Metaloproteinase 1 da Matriz , Epitopos , Polímeros/química , Pepsina A , Peptídeos , Poli A
9.
Crit Rev Food Sci Nutr ; : 1-34, 2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36300633

RESUMO

In the global market era, food product control is very challenging. It is impossible to track and control all production and delivery chains not only for regular customers but also for the State Sanitary Inspections. Certified laboratories currently use accurate food safety and quality inspection methods. However, these methods are very laborious and costly. The present review highlights the need to develop fast, robust, and cost-effective analytical assays to determine food contamination. Application of the molecularly imprinted polymers (MIPs) as selective recognition units for chemosensors' fabrication was herein explored. MIPs enable fast and inexpensive electrochemical and optical transduction, significantly improving detectability, sensitivity, and selectivity. MIPs compromise durability of synthetic materials with a high affinity to target analytes and selectivity of molecular recognition. Imprinted molecular cavities, present in MIPs structure, are complementary to the target analyte molecules in terms of size, shape, and location of recognizing sites. They perfectly mimic natural molecular recognition. The present review article critically covers MIPs' applications in selective assays for a wide range of food products. Moreover, numerous potential applications of MIPs in the food industry, including sample pretreatment before analysis, removal of contaminants, or extraction of high-value ingredients, are discussed.

10.
Artigo em Inglês | MEDLINE | ID: mdl-35838159

RESUMO

Herein, we report the potential-driven electrochemical transformation carried out in basic media of two Ni2+ salen polymers, (poly(NiSalen)s), abbreviated as poly(meso-NiSaldMe) and poly(NiSaltMe). These two polymers, with different configurations of methyl substituents on the imine bridge, were used as precursors for the preparation of electrocatalytically active nickel hydroxide [Ni(OH)2]-type nanoparticles (NPs) anchored in the polymeric matrix as poly[SalenNi(OH)2]. The use of potentiodynamic and potentiostatic electropolymerization conditions for the deposition of polymeric precursors allowed us to control the molecular architecture of poly(NiSalen)s and NPs derived from them. Thus, we obtained different arrangements of NPs embedded in morphologically different poly(Salen) matrixes, indicating their electrocatalytic activity toward ethanol to different extents. Moreover, we found a direct relationship between the electrochemical stability of the poly(NiSalen) precursors operating in the organic solvent-based electrolyte solutions and the easiness of their transformation into Ni(OH)2 NPs operating in the aqueous alkaline media. Poly(NiSalen)s and Ni(OH)2-type NPs were characterized by X-ray photoelectron spectroscopy, scanning electron microscopy, and transmission electron microscopy.

11.
Biosens Bioelectron ; 208: 114203, 2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35395618

RESUMO

A conducting molecularly imprinted polymer (MIP) film was integrated with an extended-gate field-effect transistor (EG-FET) transducer to determine epitopes of matrix metalloproteinase-1 (MMP-1) protein biomarker of idiopathic pulmonary fibrosis (IPF) selectively. Most suitable epitopes for imprinting were selected with Basic Local Alignment Search Tool software. From a pool of MMP-1 epitopes, the two, i.e., MIAHDFPGIGHK and HGYPKDIYSS, the relatively short ones, most promising for MMP-1 determination, were selected, mainly considering their advantageous outermost location in the protein molecule and stability against aggregation. MIPs templated with selected epitopes of the MMP-1 protein were successfully prepared by potentiodynamic electropolymerization and simultaneously deposited as thin films on electrodes. The chemosensors, constructed of MIP films integrated with EG-FET, proved useful in determining these epitopes even in a medium as complex as a control serum. The limit of detection for the MIAHDFPGIGHK and HGYPKDIYSS epitope was ∼60 and 20 nM, respectively. Moreover, the chemosensors selectively recognized whole MMP-1 protein in the 50-500 nM concentration range in buffered control serum samples.


Assuntos
Técnicas Biossensoriais , Impressão Molecular , Epitopos , Metaloproteinase 1 da Matriz , Polímeros Molecularmente Impressos
12.
Anal Chim Acta ; 1188: 339177, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34794582

RESUMO

We fabricated an electrochemical molecularly imprinted polymer (MIP) chemosensor for rapid identification and quantification of E. coli strain using 2-aminophenyl boronic acid as the functional monomer. This strain is a modified Gram-negative strain of Escherichia coli bacterium, an ordinary human gut component. The E. coli strongly interacts with a boronic acid because of porous and flexible polymers of the cell wall. The SEM imaging showed that the bacteria template was partially entrapped within the polymeric matrix in a single step. Moreover, this imaging confirmed E. coli K-12 cell template extraction effectiveness. The prepared MIP determined the E. coli K-12 strain up to 2.9 × 104 cells mL-1. The interference study performed in the presence of E. coli variants expressing different surface appendages (type 1 fimbriae or Antigen 43 protein) or Shewanella oneidensis MR1, another Gram-negative bacteria, demonstrated that the bacterial surface composition notably impacts sensing properties of the bacteria imprinted polymer.


Assuntos
Escherichia coli K12 , Impressão Molecular , Receptores Artificiais , Polímeros Molecularmente Impressos , Shewanella
13.
J Agric Food Chem ; 69(48): 14689-14698, 2021 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-34841873

RESUMO

Inspired by the easy intercalation of quinoxaline heterocyclic aromatic amines (HAAs) in double-stranded DNA (dsDNA), we synthesized a nucleobase-functionalized molecularly imprinted polymer (MIP) as the recognition unit of an impedimetric chemosensor for the selective determination of a 2-amino-3,7,8-trimethyl-3H-imidazo[4,5-f]quinoxaline (7,8-DiMeIQx) HAA. HAAs are generated in meat and fish processed at high temperatures. They are considered to be potent hazardous carcinogens. The MIP film was prepared by potentiodynamic electropolymerization of a pre-polymerization complex of two adenine- and one thymine-substituted bis(2,2'-bithien-5-yl)methane functional monomer molecules with one 7,8-DiMeIQx template molecule, in the presence of the 2,4,5,2',4',5'-hexa(thiophene-2-yl)-3,3'-bithiophene cross-linking monomer, in solution. The as-formed MIP chemosensor allowed for the selective impedimetric determination of 7,8-DiMeIQx in the 47 to 400 µM linear dynamic concentration range with a limit of detection of 15.5 µM. The chemosensor was successfully applied for 7,8-DiMeIQx determination in the pork meat extract as a proof of concept.


Assuntos
Impressão Molecular , Carne de Porco , Carne Vermelha , Aminas , Animais , DNA , Eletrodos , Polímeros Molecularmente Impressos , Suínos
14.
Biosens Bioelectron ; 193: 113542, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34391178

RESUMO

Molecularly imprinted polymer (MIP) nanoparticles-based differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) chemosensors for antiplatelet drug substance, cilostazol (CIL), and its pharmacologically active primary metabolite, 3,4-dehydrocilostazol (dhCIL), selective determination in human plasma were devised, prepared, and tested. Molecular mechanics (MM), molecular dynamics (MD), and density functional theory (DFT) simulations provided the optimum structure and predicted the stability of the pre-polymerization complex of the CIL template with the chosen functional acrylic monomers. Moreover, they accounted for the MIP selectivity manifested by the molecularly imprinted cavity with the CIL molecule complex stability higher than that for each interference. On this basis, a fast and reliable method for determining both compounds was developed to meet an essential requirement concerning the personalized drug dosage adjustment. The limit of detection (LOD) at the signal-to-noise ratio of S/N = 3 in DPV and EIS determinations using the ferrocene redox probe in a "gate effect" mode was 93.5 (±2.2) and 86.5 (±4.6) nM CIL, respectively, and the linear dynamic concentration range extended from 134 nM to 2.58 µM in both techniques. The chemosensor was highly selective to common biological interferences, including cholesterol and glucose, and less selective to structurally similar dehydroaripiprazole. Advantageously, it responded to dhCIL, thus allowing for the determination of CIL and dhCIL together. The EIS chemosensor appeared slightly superior to the DPV chemosensor concerning its selectivity to interferences. The CIL DPV sorption data were fitted with Langmuir, Freundlich, and Langmuir-Freundlich isotherms. The determined sorption parameters indicated that the imprinted cavities were relatively homogeneous and efficiently interacted with the CIL molecule.


Assuntos
Técnicas Biossensoriais , Impressão Molecular , Nanopartículas , Preparações Farmacêuticas , Cilostazol , Técnicas Eletroquímicas , Eletrodos , Humanos , Limite de Detecção , Polímeros Molecularmente Impressos
16.
ACS Sens ; 5(1): 118-126, 2020 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-31845570

RESUMO

Homogenous nanostructuration of molecularly imprinted polymer (MIP) films for follicle-stimulating hormone (FSH)-sensing was achieved by using optimized colloidal crystals as a hard mold. Introduction of a heating step after assembling colloidal crystals of silica beads promoted their adhesion. Thus, precise assembling of beads was not disturbed during further multisteps of surface imprinting, and crack-free hexagonal packing was maintained. Scanning electron microscopy imaging confirmed hexagonal packing of silica colloidal crystals as well as homogenous nanostructuration in MIP films. FSH immobilization over silica beads and later its derivatization with electroactive functional monomers was confirmed by X-ray photoelectron spectroscopy analysis. The nanostructured molecular recognition films prepared in this way were combined with an electrochemical transducer in order to design a capacitive impedimetry-based chemosensing system. It was tested for the determination of FSH in the range from 0.1 fM to 100 pM in 10 mM 2-(N-morpholino) ethane sulfonic acid buffer (pH = 4.2). The detection limit of the chemosensor was 0.1 fM, showing a high selectivity with respect to common protein interferences as well as other protein hormones of the gonadotropin family.


Assuntos
Técnicas Biossensoriais/métodos , Hormônio Foliculoestimulante/química , Impressão Molecular/métodos , Polímeros/química , Humanos
17.
Anal Chem ; 91(12): 7546-7553, 2019 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-31124353

RESUMO

The "gate effect" mechanism for conductive molecularly imprinted polymer (MIP) film coated electrodes was investigated in detail. It was demonstrated that the decrease of the DPV signal for the Fe(CN)64-/Fe(CN)63- redox probe with the increase of the p-synephrine target analyte concentration in solution at the polythiophene MIP-film coated electrode did not originate from swelling or shrinking of the MIP film, as it was previously postulated, but from changes in the electrochemical process kinetics. The MIP-film coated electrode was examined with cyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and surface plasmon resonance (SPR). The MIP-film thickness in the absence and in the presence of the p-synephrine analyte was examined with in situ AFM imaging. Moreover, it was demonstrated that doping of the MIP film was not affected by p-synephrine binding in MIP-film molecular cavities. It was concluded that the "gate effect" was most likely caused by changes in radical cation (polaron) mobility in the film.

18.
Biosens Bioelectron ; 109: 50-62, 2018 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-29525669

RESUMO

Molecular recognition, i.e., ability of one molecule to recognize another through weak bonding interactions, is one of the bases of life. It is often implemented to sensing systems of high merits. Preferential recognition of the analyte (guest) by the receptor (host) induces changes in physicochemical properties of the sensing system. These changes are measured by using suitable signal transducers. Because of possibility of miniaturization, fast response, and high sensitivity, field-effect transistors (FETs) are more frequently being used for that purpose. A FET combined with a biological material offers the potential to overcome many challenges approached in sensing. However, low stability of biological materials under measurement conditions is a serious problem. To circumvent this problem, synthetic receptors were integrated with the gate surface of FETs to provide robust performance. In the present critical review, the approach utilized to devise chemosensors integrating synthetic receptors and FET transduction is discussed in detail. The progress in this field was summarized and important outcome was provided.


Assuntos
Técnicas Biossensoriais , Receptores Artificiais/química , Transistores Eletrônicos , Humanos
19.
Biosens Bioelectron ; 100: 251-258, 2018 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-28934696

RESUMO

By means of molecular imprinting of a conducting polymer, molecular cavities selective for oxytocin nonapeptide, an autism biomarker, were designed. Embedding of the oxytocin template, and then its extracting from the molecularly imprinted polymer (MIP) was confirmed by the XPS analysis. AFM imaging of the MIP film surface indicated changes in mechanical properties of the film after template extraction. The MIP synthetic receptor was deposited by potentiodynamic electropolymerization as a thin film on an Au film electrode in an electrochemical miniaturized microfluidic cell. The use of this cell allowed to shorten analysis time and to decrease the sample volume. The linear dynamic concentration range extended from 0.06 to 1mM with the limit of detection of 60µM (S/N = 3). Advantageously, sensitivity of the diagnostic microfluidic platform devised for oxytocin determination in both synthetic serum samples and in aqueous solutions was similar and, moreover, it was selective to common interferences, such as oxytocin analogs and potential metabolites.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Impressão Molecular/métodos , Ocitocina/sangue , Polímeros/química , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Desenho de Equipamento , Ouro/química , Humanos , Limite de Detecção , Técnicas Analíticas Microfluídicas/métodos , Ocitocina/análise
20.
Biosens Bioelectron ; 94: 155-161, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28284074

RESUMO

Nanostructured artificial receptor materials with unprecedented hierarchical structure for determination of human serum albumin (HSA) are designed and fabricated. For that purpose a new hierarchical template is prepared. This template allowed for simultaneous structural control of the deposited molecularly imprinted polymer (MIP) film on three length scales. A colloidal crystal templating with optimized electrochemical polymerization of 2,3'-bithiophene enables deposition of an MIP film in the form of an inverse opal. Thickness of the deposited polymer film is precisely controlled with the number of current oscillations during potentiostatic deposition of the imprinted poly(2,3'-bithiophene) film. Prior immobilization of HSA on the colloidal crystal allows formation of molecularly imprinted cavities exclusively on the internal surface of the pores. Furthermore, all binding sites are located on the surface of the imprinted cavities at locations corresponding to positions of functional groups present on the surface of HSA molecules due to prior derivatization of HSA molecules with appropriate functional monomers. This synergistic strategy results in a material with superior recognition performance. Integration of the MIP film as a recognition unit with a sensitive extended-gate field-effect transistor (EG-FET) transducer leads to highly selective HSA determination in the femtomolar concentration range.


Assuntos
Técnicas Biossensoriais/métodos , Impressão Molecular , Albumina Sérica Humana/isolamento & purificação , Humanos , Polímeros/química , Tiofenos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...